Product detail:
1.Special functions for the disabled: It applies horizontal installation of buttons in the elevator car. It also prints braille in the buttons. It is convenient for the disabled to enter into / exit from the elevator.
2.It prolongs time-delay door-closing. After the elevator fully opens the door, it keeps door-opening. After time-delay, it automatically closes the door. It is convenient for the medical staff to safely enter into / exit from the elevator.
Hospital elevator specification:
| Load(kg) | Persons | Speed(m/s) | Door open type | Entrance | Car net size | Shaft inside dimension | Machine room size | |||
| (JJ*HH)mm | (AA*BB)mm | (AH*BH)mm | PP | OH | (W*D)mm | |||||
| Single | Opposite(optional) | |||||||||
| 1600 | 21 | 0.63/1.0 | 2-panel side opening | 1200*2100 | 1400*2400 | 2400*3000 | 2400*3060 | 1500 | 4500 | 3200*4200*2800 |
| 1.5/1.75 | 1800 | 4800 | ||||||||
| 0.63/1.0 | Center-opening | 1000*2100 | 2500*2900 | 2500*2930 | 1500 | 4500 | ||||
| 1.5/1.75 | 1800 | 4800 | ||||||||
| 2000 | 26 | 0.63/1.0 | 2-panel side opening | 1300*2100 | 1500*2700 | 2500*3300 | 2500*3360 | 1500 | 4500 | 3300*4300*2800 |
| 1900 | ||||||||||
| Center-opening | 1100*2100 | 2600*3200 | 2600*3230 | 1500 | ||||||
| 1900 | ||||||||||
MRL hospital elevator specification:
| Load(kg) | Persons | Speed(m/s) | Entrance | Car net size | Shaft inside dimension | ||
| (JJ*HH)mm | (AA*BB)mm | (AH*BH)mm | PP | OH | |||
| 630 | 8 | 1.0 | 800*2100 | 1300*1250 | 2250*1700 | 1600 | 4000 |
| 1.5/1.75 | 1800 | 4300 | |||||
| 800 | 10 | 1.0 | 800*2100 | 1400*1400 | 2400*1900 | 1600 | 4200 |
| 1.5/1.75 | 1800 | 4500 | |||||
| 1000 | 13 | 1.0 | 900*2100 | 1500*1600 | 2500*2100 | 1600 | 4200 |
| 1.5/1.75 | 1800 | 4500 | |||||
| 1600 | 21 | 0.63/1.0 | 1000*2100 | 1900*1850 | 3000*2400 | 1600 | 4600 |
| 2.0/2.5 | |||||||
Function:
| Standard function: | ||
| Travel function | 1 | VVVF drive |
| 2 | VVVF door operator | |
| 3 | Independent running | |
| 4 | Automatic pass without stop | |
| 5 | Automatically adjust door opening time | |
| 6 | Reopen with hall call | |
| 7 | Express door closing | |
| 8 | Car stops and door open | |
| 9 | Car arrival gong | |
| 10 | Command register cancel | |
| Safety function | 11 | Light curtain protection |
| 12 | Designated stop | |
| 13 | Overload holding stop | |
| 14 | Anti-stall timer protection | |
| 15 | Start protection control | |
| 16 | Inspection operation | |
| 17 | Fault self-diagnosis | |
| 18 | Repeated door closing | |
| 19 | Up/down over-run and final limit protection | |
| 20 | Down over-speed protection device | |
| 21 | Up over-speed protection device | |
| Human-machine Interface | 22 | Micro-touch button for car call and hall call |
| 23 | Floor and direction indicator inside car | |
| 24 | Floor and direction indicator | |
| Emergency function | 25 | Emergency lighting |
| 26 | Inching running | |
| 27 | Five way intercom | |
| 28 | bell | |
| 29 | Fire emergency return | |
| Energy-saving function | 30 | Car fans/lighting automatic shut-off |
| 31 | Remote shut-off | |
| Optional Function | ||
| Emergency function | 1 | Leveling when power off |
| Travel function | 2 | Anti-nuisance |
| 3 | Open the door in advance | |
| 4 | Direct parking | |
| 5 | Group control function | |
| 6 | Duplex control | |
| 7 | On-duty peak service | |
| 8 | Off-duty peak service | |
| 9 | Door open time extending | |
| Human-machine Interface | 10 | Voice announcer |
| 11 | Car assistant operation box | |
| 12 | Operation box for the handicapped | |
| 13 | Intelligent calling service | |
| 14 | IC card control function | |
| Monitor function | 15 | Remote monitor |
| 16 | Remote control | |
| 17 | Car camera | |
Note:The above data is only for your reference. If you have any special request ,pls do not hesitate to contact with us anytime .